Commit e78460bf authored by Topi Rasku's avatar Topi Rasku
Browse files

WIP datastore template description updates.

parent dac74bdd
......@@ -710,196 +710,196 @@
"down",
null,
null,
null
"Downwards reserve provision data for units"
],
[
"p_gnuReserves",
"portion_of_infeed_to_reserve",
null,
null,
null
"Proportion of the generation of a tripping unit that needs to be covered by reserves from other units"
],
[
"p_gnuReserves",
"up",
null,
null,
null
"Upwards reserve provision data for units"
],
[
"p_gnu_io",
"annuity",
null,
null,
null
"Investment annuity factor"
],
[
"p_gnu_io",
"capacity",
null,
null,
null
"Maximum capacity (MW)"
],
[
"p_gnu_io",
"conversionCoeff",
null,
null,
null
"Coefficient for conversion equation (multiplies each input or output when summing v_gen from multiple inputs/outputs)"
],
[
"p_gnu_io",
"initialGeneration",
null,
null,
null
"Initial generation/consumption of the unit in the first time step (MW)"
],
[
"p_gnu_io",
"invCosts",
null,
null,
null
"Investment costs (EUR/MW)"
],
[
"p_gnu_io",
"maxRampDown",
null,
null,
null
"Speed to ramp down (p.u./min)"
],
[
"p_gnu_io",
"maxRampUp",
null,
null,
null
"Speed to ramp up (p.u./min)"
],
[
"p_gnu_io",
"unitSize",
null,
null,
null
"Input/Output capacity of one subunit for integer investments (MW)"
],
[
"p_gnu_io",
"useInitialGeneration",
null,
null,
null
"A flag to indicate whether to fix generation for the first time step (binary)"
],
[
"p_gnu_io",
"vomCosts",
null,
null,
null
"Variable operation and maintenance costs (EUR/MWh)"
],
[
"p_groupPolicyEmission",
"emissionTax",
null,
null,
null
"Emission tax (EUR/tonne)"
],
[
"p_groupReserves",
"down",
null,
null,
null
"TODO: Add proper explanation."
],
[
"p_groupReserves",
"reserve_activation_duration",
null,
null,
null
"How long the reserve should be provided once activated (h)"
],
[
"p_groupReserves",
"reserve_length",
null,
null,
null
"Length of reserve horizon (number of timesteps)"
],
[
"p_groupReserves",
"reserve_reactivation_time",
null,
null,
null
"How soon the unit providing reserve needs to be able to reactivate after the start of the previous activation (h)"
],
[
"p_groupReserves",
"up",
null,
null,
null
"TODO: Add proper explanation."
],
[
"p_groupReserves",
"update_frequency",
null,
null,
null
"Frequency of updating reserve contributions (number of timesteps)"
],
[
"p_groupReserves3D",
"LossOfTrans",
null,
null,
null
"A flag to tell that N-1 reserve is needed due to a possibility that an interconnector to/from the node group fails"
],
[
"p_groupReserves3D",
"ts_reserveDemand",
null,
null,
null
"Reserve demand in region in the time step (MW)"
],
[
"p_groupReserves4D",
"ReserveShareMax",
null,
null,
null
"Maximum reserve share of a group of units"
],
[
"p_nEmission",
"emission_content",
null,
null,
null
"Emission content (kg/MWh)"
],
[
"p_uStartupFuel",
"fixedFuelFraction",
null,
null,
null
"Fixed share of a fuel in the consumption mix"
],
[
"p_unitConstraint",
"constant",
null,
null,
null
"Constant when binding inputs/outputs"
],
[
"p_unitConstraintNode",
"coefficient",
null,
null,
null
"Coefficient when binding inputs/outputs"
],
[
"uGroup",
"constrainedOnlineMultiplier",
null,
null,
null
"Multiplier a(i) for online units in equation Sum(i, a(i)*v_online(i)) <= b"
]
]
}
\ No newline at end of file
Supports Markdown
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment